Cookies on this website

We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

© 2015 John Wiley & Sons, Ltd. The purpose of this work was to harmonize data acquisition and post-processing of single voxel proton MRS (1H-MRS) at 7T, and to determine metabolite concentrations and the accuracy and reproducibility of metabolite levels in the adult human brain. This study was performed in compliance with local institutional human ethics committees. The same seven subjects were each examined twice using four different 7T MR systems from two different vendors using an identical semi-localization by adiabatic selective refocusing spectroscopy sequence. Neurochemical profiles were obtained from the posterior cingulate cortex (gray matter, GM) and the corona radiata (white matter, WM). Spectra were analyzed with LCModel, and sources of variation in concentrations ('subject', 'institute' and 'random') were identified with a variance component analysis. Concentrations of 10-11 metabolites, which were corrected for T1, T2, magnetization transfer effects and partial volume effects, were obtained with mean Cramér-Rao lower bounds below 20%. Data variances and mean concentrations in GM and WM were comparable for all institutions. The primary source of variance for glutamate, myo-inositol, scyllo-inositol, total creatine and total choline was between subjects. Variance sources for all other metabolites were associated with within-subject and system noise, except for total N-acetylaspartate, glutamine and glutathione, which were related to differences in signal-to-noise ratio and in shimming performance between vendors. After multi-center harmonization of acquisition and post-processing protocols, metabolite concentrations and the sizes and sources of their variations were established for neurochemical profiles in the healthy brain at 7T, which can be used as guidance in future studies quantifying metabolite and neurotransmitter concentrations with 1H-MRS at ultra-high magnetic field.

Original publication

DOI

10.1002/nbm.3252

Type

Journal article

Journal

NMR in Biomedicine

Publication Date

01/01/2015

Volume

28

Pages

306 - 316