We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

Improving the prevention and detection of preinvasive ductal carcinoma in situ (DCIS) is expected to lower both morbidity and mortality from breast cancer. Transgenic mouse models can be used as a 'test bed' to develop new imaging methods and to evaluate the efficacy of candidate preventive therapies. We hypothesized that despite its microscopic size, early murine mammary cancer, including DCIS, might be accurately detected by MRI. C3(1) SV40 TAg female mice (n=23) between 10 and 18 weeks of age were selected for study. Eleven mice were subjected to in vitro imaging using a T(2)-weighted spin echo sequence and 12 mice were selected for in vivo imaging using a T(1)-weighted gradient echo, a T(2)-weighted spin echo and high spectral and spatial resolution imaging sequences. The imaged glands were carefully dissected, formalin fixed and paraffin embedded, and then H&E stained sections were obtained. The ratio of image-detected versus histologically detected cancers was obtained by reviewing the MR images and H&E sections independently and using histology as the gold standard. MR images were able to detect 12/12 intramammary lymph nodes, 1/1 relatively large (approximately 5 mm) tumor, 17/18 small (approximately 1 mm) tumors and 13/16 ducts distended with DCIS greater than 300 microm. Significantly, there were no false positives--i.e., image detection always corresponded to a histologically detectable cancer in this model. These results indicate that MR imaging can reliably detect both preinvasive in situ and early invasive mammary cancers in mice with high sensitivity. This technology is an important step toward the more effective use of non-invasive imaging in pre-clinical studies of breast cancer prevention, detection and treatment.

Original publication

DOI

10.1088/0031-9155/53/19/014

Type

Journal article

Journal

Phys Med Biol

Publication Date

07/10/2008

Volume

53

Pages

5481 - 5493

Keywords

Animals, Carcinoma, Feasibility Studies, Magnetic Resonance Imaging, Mammary Neoplasms, Experimental, Mice, Mice, Transgenic, Microscopy