We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

This paper investigates measures to assess automatically the level of pain in a group of chronic pain patients implanted with electrodes for deep brain stimulation. Electrical activity in local field potentials in particular frequency bands has been shown to be associated with changes in the perception of pain. In this paper we develop a method to classify pain intensity with two groups of patients, one with electrodes implanted in the thalamus (VPL) and the other with implants in periaqueductal grey (PAG/PVG), using wavelet analysis to process the local field potential data from the deep brain electrodes. A fuzzy network classifier is used to relate sections of the data to the pain intensity, as recorded by patients using a visual analogue scale (VAS) scale. Our results suggest that in the PAG implanted patients alpha activity is a good measure of pain in a single patient, whereas correlation with beta activity is more appropriate in thalamus implanted patients. The relation between such activity and pain level shows some consistency within a session. This suggests that a closed loop form of DBS may be possible for these patients to optimize their treatment. However it was not possible to train a classifier consistently across the groups of patients, possibly because of differences in pain perception across individuals. © 2013 IEEE.

Original publication

DOI

10.1109/NER.2013.6696153

Type

Conference paper

Publication Date

01/12/2013

Pages

1194 - 1197