We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

Severity scoring systems are tools that provide a predicted mortality for a group of intensive care unit patients on the basis of derangement of their physiology and some past medical history. This predicted mortality can then be compared with the actual mortality to give some indicator of the effectiveness of the package of care delivered by the intensive care unit, corrected for differences in case-mix. Thus, their primary use is in audit, and they are designed for use on large populations of patients and not on individuals. In spite of a large number of publications on the development, refinement and testing of scoring systems, papers describing their use in comparative audit are very rare. This may be partly due to limitations in their ability to predict mortality outside the population on which they were developed, and to the change in calibration of the system with time and advances in medical science. This review briefly addresses the limitations of severity scoring systems in light of recent publications.

Type

Journal article

Journal

Curr Opin Anaesthesiol

Publication Date

04/2000

Volume

13

Pages

203 - 207