Cookies on this website

We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

T2*-weighted imaging of the spinal cord suffers from signal dropouts that hamper blood-oxygenation-level-dependent functional magnetic resonance imaging (fMRI). They are due to field inhomogeneities caused by the different magnetic susceptibilities of the vertebrae and the intervertebral disks that vary periodically along the cord and, thus, cannot be compensated appropriately with conventional (constant) shimming. In this study, a single, slice-specific gradient pulse ("z-shim") is applied in echo-planar imaging of axial sections in order to compensate for the corresponding through-slice signal dephasing without affecting the acquisition time, i.e. the temporal resolution. Based on a reference acquisition sampling a range of compensation moments, the value yielding the maximum signal amplitude within the spinal cord is determined for each slice. Severe N/2 ghosting for larger compensation moments is avoided by applying the gradient pulse after the corresponding reference echoes. Furthermore, first-order flow compensation in the slice direction of both the slice-selection and the z-shim gradient pulse considerably reduces signal fluctuations in the cerebro-spinal fluid surrounding the spinal cord, i.e. would minimize ringing artifacts in fMRI. Phantom and in vivo experiments show the necessity to use slice-specific compensation moments in the presence of local susceptibility differences. Measurements performed in a group of 24 healthy volunteers at 3T demonstrate that this approach improves T2*-weighted imaging of axial sections of the cervical spinal cord by (i) increasing the signal intensity (overall by about 20%) and (ii) reducing signal intensity variations along the cord (by about 80%). Thus, it may help to improve the feasibility and reliability of fMRI of the spinal cord.

Original publication

DOI

10.1016/j.neuroimage.2011.09.038

Type

Journal article

Journal

Neuroimage

Publication Date

01/02/2012

Volume

59

Pages

2307 - 2315

Keywords

Algorithms, Echo-Planar Imaging, Humans, Image Processing, Computer-Assisted, Magnetic Resonance Imaging, Oxygen, Phantoms, Imaging, Spinal Cord, Whole Body Imaging