Cookies on this website

We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

BACKGROUND: Carotid artery intraplaque hemorrhage (IPH), an unstable component of atherosclerosis, is associated with an increased risk of stroke. PURPOSE: To investigate quantitative susceptibility mapping (QSM) as a tool for the evaluation of IPH and calcification in vivo. STUDY TYPE: Prospective. POPULATION: Ten healthy volunteers and 15 patients. FIELD STRENGTH/SEQUENCE: 3.0T Susceptibility-weighted imaging (SWI), magnetization-prepared rapid acquisition with gradient echo (MP-RAGE), T1 -weighted sampling perfection with application of optimized contrasts using different flip angle evolution (T1 -SPACE), T2 -weighted turbo spin-echo (T2 WI), and time-of-flight (TOF) sequences. ASSESSMENT: The vessel wall area of the carotid artery was measured with QSM and compared with T1 -SPACE on healthy volunteers. Four radiologists, blinded to clinical history and patient identity, determined the presence and area of IPH on MP-RAGE and QSM, as well as the area of calcification on T1 -SPACE and QSM. STATISTICAL TESTS: Bland-Altman analysis, Pearson correlation coefficients, linear regression analyses were performed to evaluate the concordance of area measurements. Cohen's kappa (κ) was analyzed to determine the agreement between IPH detections. The paired t-test was used to compare the group differences. RESULTS: In 423 matched slices, 20.1% (85/423) and 19.6% (83/423) were detected to have IPH on MP-RAGE and QSM, respectively. IPH detection by QSM and MP-RAGE showed good agreement (κ = 0.822, P < 0.001) between the two methods. There was no significant difference in IPH area measurements between QSM and MP-RAGE (7.28 mm2  ± 6.41 vs. 7.16 mm2  ± 5.99, P = 0.575). There was no significant difference in calcification area measurement between QSM and T1 -SPACE (3.51 mm2  ± 1.78 vs. 3.41 mm2  ± 2.02, P = 0.783). DATA CONCLUSION: QSM is a novel imaging tool for the identification of IPH in patients with carotid atherosclerosis and enables differentiation of IPH and calcification. EVIDENCE LEVEL: 1 TECHNICAL EFFICACY: Stage 1.

Original publication

DOI

10.1002/jmri.27064

Type

Journal article

Journal

J Magn Reson Imaging

Publication Date

10/02/2020

Keywords

calcification, carotid atherosclerosis, intraplaque hemorrhage, quantitative susceptibility mapping